MWIR LED research and design enquiries for the 3–5μm band
R&D documents and samples
Send the target gas, wavelength, detector and quantity so we can confirm model documentation and evaluation availability.
R&D specifications and sample availability are reconfirmed at the time of enquiry.
Supply and review scope
Published MWIR models: 3.1–4.3μm
The models documented on this page span 3,100–4,300nm. Other wavelengths in the broader 3–5μm band require individual confirmation.
R&D stage
Electrical and optical characteristics and sample availability are confirmed by model and evaluation timing.
NDIR wavelength review
Candidate wavelengths are narrowed down together with the target gas absorption band, detector and optical path length.
Extended SWIR supplied separately
The 2,100, 2,200 and 2,300nm models are classified and listed separately as extended SWIR.
3.1–4.3μm R&D products
The table retains the existing published model values. It does not imply routine availability across the entire 3–5μm band; wavelengths outside the table require confirmation.
| Model | Peak λ | Po @300mA | Vf | Chip size | Application review |
|---|---|---|---|---|---|
| 3.1 μm LED | 3,100 nm | 0.2 mW | 0.3 V | 500×500 μm | Review near the 2,900nm band |
| 3.7 μm LED | 3,700 nm | 0.4 mW | 0.3 V | 500×500 μm | Spectroscopy research |
| 3.9 μm LED | 3,900 nm | 0.3 mW | 0.3 V | 500×500 μm | Hydrocarbon detection review |
| 4.1 μm LED | 4,100 nm | 0.4 mW | 0.3 V | 500×500 μm | Reference-channel review |
| 4.3 μm LED | 4,300 nm | 0.1 mW | 0.3 V | 500×500 μm | CO₂ NDIR review |
Extended SWIR 2.1–2.3μm
The 2,100–2,300nm models belong to the extended-SWIR supply line, not the 3–5μm MWIR band, and are therefore listed separately.
| Model | Peak λ | Po @1.0A | Vf | Chip size | Application review |
|---|---|---|---|---|---|
| 21RXBR | 2,100 nm | 20 mW | 0.8 V | 1080×1080 μm | Extended-SWIR sensing |
| 22RXBR | 2,200 nm | 12 mW | 0.8 V | 1080×1080 μm | Extended-SWIR sensing |
| 23RXBR | 2,300 nm | 6 mW | 0.8 V | 1080×1080 μm | CO-band review |
Selected molecular absorption bands
These values are absorption-band references for initial wavelength review, not a product-availability list. Sensor design must also consider the gas spectrum, detector and filter.
MWIR and extended-SWIR review by target
Published model wavelengths are distinguished from absorption-band references. Proximity to an absorption band does not by itself establish suitability; system evaluation is required.
| Target | Review wavelength | Supply and design note |
|---|---|---|
| CO₂ | 4,300 nm | A published 4.3μm MWIR model is listed; evaluate it with the detector and filter. |
| CO | 2,300 / 4,600 nm | 2,300nm is the 23RXBR extended-SWIR model. 4,600nm is an absorption reference and is not in the published model table. |
| Methane (CH₄) | 3,300 nm | Absorption-band reference. No 3,300nm model is listed in the published product table. |
| Hydrocarbons | 3,900 nm | Review the published 3.9μm MWIR model as an evaluation candidate. |
| Reference channel | 4,100 nm | A published 4.1μm MWIR model; confirm reference suitability against the target-gas spectrum. |
Frequently asked questions
Q.Is 2,300nm an MWIR LED?+
Q.What published MWIR model range is shown?+
Q.How do I request documents and samples?+
View products
SWIR LED
1,040 – 1,650nm · extended 1,720/1,900nm
Standard 1.04–1.65μm and extended 1.72/1.90μm models.
SWIR LEDOptical Lenses & Filters
Fused Silica · Sapphire · Ge · ZnSe
Precision-grade optics from UV through IR.
Optical Lenses & FiltersGaAs Wafer
DOWA conductive · SI/EPI separately sourced
DOWA conductive VGF wafers. Semi-insulating and EPI options are separately sourced with manufacturer and origin identified.
GaAs WaferSend the target gas and optical conditions
Share the target gas, detector, wavelength, optical path and quantity. We will distinguish published models from items requiring confirmation.